VENUSの台頭: AIを活用した原子スケール3Dイメージングの新たな夜明け(VENUS rising: A new dawn for AI-powered atomic-scale 3D imaging)

ad

2024-08-29 オークリッジ国立研究所(ORNL)

オークリッジ国立研究所(ORNL)の新しい中性子散乱装置「VENUS」は、人工知能を利用して原子レベルでの高解像度3Dイメージングを実現します。VENUSは、エネルギー貯蔵や材料科学、植物生理学などの分野での研究を進化させることが期待されており、実験中にAIを活用して迅速に3Dモデルを生成することで、研究の効率を大幅に向上させます。この装置は、従来の方法では損傷を受けやすい材料を非破壊で調査することができるため、未来の研究にも大きな影響を与えるとされています。

<関連情報>

ハイパースペクトル中性子コンピュータ断層撮影装置のスキャン時間を短縮するための機械学習判断基準 A machine learning decision criterion for reducing scan time for hyperspectral neutron computed tomography systems

Shimin Tang,Singanallur V. Venkatakrishnan,Mohammad S. N. Chowdhury,Diyu Yang,Megan Gober,George J. Nelson,Maria Cekanova,Alexandru S. Biris,Gregery T. Buzzard,Charles A. Bouman,Harley D. Skorpenske & Hassina Z. Bilheux
Scientific Reports  Published:02 July 2024
DOI:https://doi.org/10.1038/s41598-024-63931-x

VENUSの台頭: AIを活用した原子スケール3Dイメージングの新たな夜明け(VENUS rising: A new dawn for AI-powered atomic-scale 3D imaging)

Abstract

We present the first machine learning-based autonomous hyperspectral neutron computed tomography experiment performed at the Spallation Neutron Source. Hyperspectral neutron computed tomography allows the characterization of samples by enabling the reconstruction of crystallographic information and elemental/isotopic composition of objects relevant to materials science. High quality reconstructions using traditional algorithms such as the filtered back projection require a high signal-to-noise ratio across a wide wavelength range combined with a large number of projections. This results in scan times of several days to acquire hundreds of hyperspectral projections, during which end users have minimal feedback. To address these challenges, a golden ratio scanning protocol combined with model-based image reconstruction algorithms have been proposed. This novel approach enables high quality real-time reconstructions from streaming experimental data, thus providing feedback to users, while requiring fewer yet a fixed number of projections compared to the filtered back projection method. In this paper, we propose a novel machine learning criterion that can terminate a streaming neutron tomography scan once sufficient information is obtained based on the current set of measurements. Our decision criterion uses a quality score which combines a reference-free image quality metric computed using a pre-trained deep neural network with a metric that measures differences between consecutive reconstructions. The results show that our method can reduce the measurement time by approximately a factor of five compared to a baseline method based on filtered back projection for the samples we studied while automatically terminating the scans.

2004放射線利用
ad
ad
Follow
ad
タイトルとURLをコピーしました